Skip to main content Skip to footer
aptechnologies

Call Us On01225 780400

For APT Solutions

  • Visible spectrometers for biomedical applications
  • Ultracompact spectrometers for portable applications
  • High performance spectrometers for quality control
  • High accuracy spectrometers for LED, VCSEL and Laser Diode manufacture
  • Spectrometers for process control and air-quality monitoring
  • Compact handheld instrument incorporating UltraMicro MEMS spectrometer
  • High speed spectrometers for process control
  • UltraMicro MEMS grating-collimator micro-spectrometer
Previous Next

SW LogoOtO Photonics' SideWinder Series of Czerny-Turner cavity spectrometers are specifically designed for operation in the near infrared region.

 

The SideWinder range is divided into four product families dependent on wavelength range and thermal management options:-

 

SW25xx: 900-1700nm wavelength range with a choice of 128-, 256- and 512-pixel non-cooled sensor.

 

SW28xx: Single-stage TE-cooled 900-1700nm operation with a choice of  256- or 512-pixel sensor.

 

SW2930: Two-stage TE-cooled 910-2200nm spectral range with a 256-pixel extended-response sensor.

 

SW29xx: Two-stage TE-cooled 900-2500nm spectral range with options of 256- or 512-pixel extended-response sensor.

 

The TE-cooled SideWinder models may be specified with an optional shutter which may be controlled via OtO's SpectraSmart spectral measurement software or by customer's own code. The shutter allows users to take dark spectra measurements and so improve accuracy of the dark background removal. These models (SW2860S, SW2870S, SW2930S, SW2960S and SW2970S) are the recommended versions. 

 

Description SW2520 SW2560 SW2570 SW2860
SW2860S
SW2870
SW2870S
SW2930
SW2930S
SW2960
SW2960S
SW2970
SW2970S
InGaAs
Sensor
128 pixel
Hamamatsu
G8160
256 pixel
Hamamatsu
G11620-
256DA
512 pixel
Hamamatsu
G11620-
512DA
1-stage TEC
256 pixel
Hamamatsu
G11620-
256SA
1-stage TEC
512 pixel
Hamamatsu
G11620-
512SA
 2-stage TEC
256 pixel
Hamamatsu
G11477-
256WB
2-stage TEC
256 pixel
Hamamatsu
G11478-
256WB
2-stage TEC
512 pixel
Hamamatsu
G11478-
512WB
Wavelength Range 900nm - 1700nm 910 - 2200nm 900 - 2500nm

  

Each SideWinder model is offered with a standard grating(s) but can be specified with a choice of slit width to optimise the Resolution/Sensitivity compromise, these are shown below.

 

Model Groove Density
(g/mm)
Blaze Angle
Spectral
Range
Resolution (nm)
25µm 50µm 100µm 150µm 200µm
SW2520 120 1000nm NIRA 900-1650nm
NIRB 950-1700nm
N/A ≤15 ≤21 ≤22 ~
SW2560 236.8 1350nm NIRC 900-1700nm N/A ≤7.2 ≤10 ≤13 ≤14
SW2570 236.8 1350nm NIRC 900-1700nm ≤4.1 ≤5.2 ≤7 ≤13 ≤14
SW2860S 236.8 1350nm NIRC 900-1700nm N/A ≤7.2 ≤10 ≤13 ≤13.8
SW2870S 236.8 1350nm NIRC 900-1700nm ≤4.1 ≤5.2 ≤7 ≤12 ≤14
SW2930S  150 1250nm NIRT 910-2200nm ≤6.5 ≤7 ≤13 ~ ≤24
SW2960S 120 1800nm NIRD 900-2500nm N/A ≤15 ≤20.3 N/A N/A
SW2970S 120 1800nm NIRD 900-2500nm ≤8.5 ≤10.7 ≤17 ~ ≤33.3

 

When selecting the slit width bear in mind that although a narrower slit improves the FWHM resolution it will also reduce the signal into the spectrometer cavity and so has lower sensitivity.

 

adobe pdf icon SideWinder product brief
adobe pdf icon SideWinder data sheet

 

For more information and to discuss your application please Contact Us.